The company securing the best performance with innovative technology
This is a composite reaction technology that mixes plasma ion (active oxygen/radical) and stinking gas after changing active oxygen into radical hydroxide in a low temperature plasma reactor and then decomposes it in a porous material.
Distinction | Structure part | Function |
---|---|---|
Deodorizer | Corona Discharge Part | Leading a plasma phenomenon through high voltage (corona) discharge |
Leading oxidation and decomposition of stinking gas by generating active ions | ||
Catalyst Part | Improving stinking gas deodorization efficiency by activating an oxidation reaction through a catalyst |
Comparison Item | Corona Ion Catalyst | Adsorption Type | Medical Fluid Washing Type |
---|---|---|---|
Process Overview | Oxidating bad smells using corona discharge, plasma ion and catalysts | Filtering bad smells using adsorption ability of activated carbon | Chemical reaction by an aqueous solution including water, acid and alkali |
Advantage | Effective for compound odor Strong against load changes Low generation of secondary pollutants Eco-friendly |
Easy to construct Affordable price |
Simple system Effective for substances with high reaction with a medical fluid |
Disadvantage | Pre-process system required when excessive moisture is generated | Frequent replacement Secondary pollution by bleaching |
Difficult to maintain A lot of chemical wastewater generated Serious corrosion of a system |
Applicability | Can be applied to remove various bad smells besides places with compound odor | Applicable to low concentration bad smells | Applicable to particular places besides places with compound odor |
System expense | Moderate | Low | Moderate |
Maintenance expense | Low | High | High |
Busan W. Office | 80CMM |
Tancheon Total Phosphorus Treatment System | 120CMM, 10CMM |
Busan Suyoung Sewage Treatment System | 400CMM |
This is a technology that separates ammonia from water through contact with air after changing ammonium ion in water into ammonia through pH control. This is the level that can treat high concentration ammonia biologically for wastewater that cannot be treated using the previous biological denitrification process. It is a technology that makes biological treatment done efficiently and stably by adjusting the C/N ratio to a suitable level by removing nitrogen in wastewater.
Purified gas is discharged as a harmless, odorless ingredient as gas and liquid are separated when the staying time of an aquatic plant passes. The purified liquid is discharged into a flux control tank and enables connected treatment to the next biological treatment process.